Q: The sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______.

Answer: Restricted to technicians who are EPA certified and refrigerant recovery

Q: A small Pliance is defined as a system that is

Answer: Manufactured, fully charged, and hermetically sealed in a factory with a charge of 5 pounds or less

Q: A __________ recovery device can be use for type 1 small appliance applications or type 2 applications if the total charge is below 15 pounds.

Answer: System dependent

Q: You must have a self-contained recovery machine available unless you only work on

Answer: Small appliances

Q: Recovery devices for use with small appliances must be capable of

Answer: Recovering 90% of the refrigerant when the compressor is operating

Q: The hydrocarbon refrigerant approved for retrofit into existing household refrigerators is

Answer: None. Hydrocarbons are not approved for any retrofit applications

Q: New household refrigerators with a charge of less than 57 grams (2 ounces weight) can use any of the following refrigerants, except.

Answer: R-1235yf

Q: And exempt refrigerant is any refrigerant that has a 0 Ozone depletion potential (0 ODP) any global warming potential (GWP) equal to or lower than carbon dioxide, that is a GWP of _________ or less.

Answer: 1

Q: What is not a small appliance?

Answer: An MVAC-like system that holds 3 pounds of R-22

Q: Any system with a charger less than ________ pounds can you system dependent recovery equipment.

Answer: 15

Q: Anytime pressurized nitrogen is put into the system, the nitrogen gas

Answer: Maybe vented to the ambient air

Q: When a tank of mixed refrigerant is sent to a reclaimer, they can

Answer: Either refuse to except the refrigerant or charge extra for processing it

Q: A passive system dependent recovery process

Answer: Recovered refrigerant in a non-pressurized container

Q: What is the pressure of a storage cylinder of R-134A, that is stored in a room where the temperature is 100°F?

Answer: 124 PSIG

Q: What is the pressure of a storage cylinder of R-404A, that is stored in a room where the temperature is 100°F?

Answer: 237 psig

Q: Any refrigerant that is vented off the top of the charging cylinder

Answer: Must be recovered

Q: Recovery of refrigerant cannot begin if the initial pressure in the system is

Answer: 0 psig

Q: What is the pressure of the storage cylinder of R-410a, that is stored in a room where the temperature is 100°F?

Answer: 319 psig

Q: To reach the necessary recovery level, when using a ________, it will most likely be essential to heat and strike the compressor with a rubber mallet to release any refrigerant.

Answer: Passive recovery devices on a small appliance with a non-operating compressor

Q: You must know the ________ before beginning a refrigerant recovery.

Answer: Type of refrigerant that is in the system

Q: Nitrogen tanks should always be equipped with a ________.

Answer: Pressure regulator and pressure relief valve downstream of the regulator

Q: If a large leak of refrigerant occurs, __________.

Answer: Immediately vacate in naturally ventilate the area

Q: A very large refrigerant leak can cause Suffocation because refrigerants

Answer: Are heavier than air and displace oxygen

Q: Always _____________ when connecting or disconnecting refrigeration hoses.

Answer: 1.) wear safety eyewear and butyl-lined gloves 2.) verify the hoses are rated for the refrigerant being used 3.) avoid trapping liquid refrigerant in the hoses

Q: CFC and HCFC refrigerants can decompose to form

Answer: Hydrochloric and hydrofluoric acids

Q: Applying heat, with a heat gun, to the compressor;

Answer: Can help vaporize any trapped liquid refrigerant during recovery.

Q: Which HC refrigerant is allowed for use in new domestic small appliances?

Answer: R-600a

Q: Technicians who perform sealed system service on small points is must have

Answer: Type 1 or universal certification

Q: Recovering multiple types of refrigerant in the same cylinder;

Answer: Will make the reclaimed refrigerants unreclaimable

Q: Type one certification is required for;

Answer: Persons handling refrigerant during maintenance, service, or repair of small appliances.

Q: Recovery equipment must be

Answer: Certified by an EPA approved testing laboratory

Q: When filling a charging cylinder with a regulated refrigerant;

Answer: The refrigerant vapor that is vented off the top of the cylinder must be recovered.

Q: Which of the following is true regarding refrigerant leaks one small appliances?

Answer: EPA does not require repair, but leaks should be repaired whenever possible.

Q: If a strong odor is detected while performing a refrigerant recovery process,

Answer: A compressor burnout has likely occurred.

Q: Small appliances are equipped with a straight piece of tubing (process stub) that is used;

Answer: As the installation location for piercing type access valve

Q: System dependent or passive recovery equipment ;

Answer: Captures refrigerant into a non-pressurized container.

Q: When pressurizing the system with nitrogen you should;

Answer: Charge through a pressure regulator and install a relief valve in the line downstream from the pressure regulator.

Q: On a system with an operating compressor, recovery equipment must be capable of recovering;

Answer: 90% refrigerant or achieving 4 inches of vacuum

Q: With a non-operating system compressor, recovery equipment must be capable of recovering;

Answer: 80% of the refrigerant or achieving 4 inches of vacuum

Q: Which of the following is an example of a noncondensible?

Answer: Air

Q: When the system is in deep vacuum;

Answer: Never energize the compressor

Q: If, after installing a fitting for the purpose of recovering the appliances refrigerant, you find that the system pressure is 0 psig;

Answer: Refrigerant recovery is not required

Q: After the refrigerant has been recovered, which of the following can be used to flush the system?

Answer: Nitrogen

Q: When using a system dependent recovery system on an appliance that has a non-operating compressor, the technician should;

Answer: Please access fitting on both the low and high side of the system

Q: System dependent recovery methods may only be used on appliances containing;

Answer: 15 pounds of refrigerant or less

Q: Self contained or active recovery equipment;

Answer: Has its own means to recover refrigerant

Q: If regulations change after the technician become certified;

Answer: The technician is responsible for complying with any changes to the regulations

Q: When using a system dependent recovery system on an appliance that has an operating compressor, the technician should;

Answer: Run the compressor and recover from the high side of the system only.

Q: Small appliances in recreational vehicles may use refrigerants such as ammonia, hydrogen, and water. These refrigerants;

Answer: Should not be recovered

Q: A small appliance is defined by EPA as;

Answer: Appliances manufactured, charged, and hermetically sealed in a factory with 5 Lbs or less of refrigerant